Back to Ma Thermopompe Hub·Cold Climate (-25 °C)

Heat Pumps in Deep Cold (-25 °C): Quebec Winter Efficiency Guide

Learn how to choose a cold-climate heat pump capable of extracting heat down to -25 °C and lowering your electricity bills during Quebec winters.

6 min read · Updated for Quebec in 2026
Heat Pumps in Deep Cold (-25 °C): Quebec Winter Efficiency Guide

Key Takeaways

  • Certified Cold Climate Heat Pumps (ccASHP) retain heating performance down to -25 °C using Inverter EVI compressor technology.
  • The Coefficient of Performance (COP) remains above 1.8 during deep freezes, consuming up to 45% less electricity than conventional baseboards.
  • The 2026 Hydro-Québec LogisVert program offers a top rate of $120 per 1,000 BTU/h at -8 °C for qualifying Cold Climate models.
Comparative efficiency by outdoor temperature
Outdoor TemperatureEstimated COPEnergy OutputAuxiliary Heat Needed
+7 °C3.8 – 4.2380% to 420%No
-8 °C (LogisVert standard)2.5 – 2.8250% to 280%No
-15 °C2.0 – 2.3200% to 230%No (when properly sized)
-25 °C (Deep Cold)1.7 – 1.9170% to 190%Occasional backup during extreme peaks

How does a heat pump extract heat at -25 °C?

A cold-climate air-source heat pump (ccASHP) extracts heat from outdoor air by evaporating refrigerant at extremely low temperatures, even during harsh winters.

Equipped with variable-speed Inverter compressors and Enhanced Vapor Injection (EVI), modern units maintain up to 80% of rated capacity at -25 °C without relying heavily on resistive electric heat.

Understanding HSPF2 ratings and winter COP performance

The Coefficient of Performance (COP) measures thermal output relative to electricity input. At mild temperatures (+7 °C), cold-climate units achieve a COP between 3.5 and 4.2.

Even at -25 °C, the COP ranges from 1.7 to 1.9, which delivers nearly double the efficiency of standard electric resistance baseboards (COP 1.0).

The role of auxiliary heating systems

During extreme cold snaps below -25 °C, existing baseboard heaters or central furnaces serve as auxiliary heat to maintain indoor setpoints.

Setting a proper balance point via a smart thermostat optimizes energy costs while extending equipment lifespan.

Take action

Estimate your rebates & energy savings

Access our self-serve calculator or get a free, direct match with a qualified local contractor.

Get my free match →Open calculator
Frequently Asked Questions

Questions asked by homeowners

What distinguishes a standard heat pump from a Cold Climate unit?

Cold Climate units feature Inverter compressors with EVI injection and pan heaters, preserving heating capacity down to -25 °C or -30 °C.

How much is the LogisVert rebate for a Cold Climate heat pump?

LogisVert 2026 provides $120 per 1,000 BTU/h capacity at -8 °C for high-efficiency Cold Climate models (versus $50/kBTU for ENERGY STAR baseline), capped at $6,700.

Should baseboard heaters be removed after installing a heat pump?

No, baseboard heaters should be kept as secondary backup during extreme winter temperature drops.